Posts that fail to meet above requirements will be removed. Suggesting the burning scrap wire to remove the insulation will result in a ban. NO DIY, SELF-HELP POSTS, OR QUESTIONS FROM NON PROFESSIONALS. Incorrect, unsafe, or hazardous information will result in a ban. This includes company names of contractors. Back it up with a code reference.ĭO NOT post any personal information. Rules Generalĭon't be a dick, and adhere to the reddiquette If you are looking for DIY or general help please visit /r/askelectricians Pre-Apprentices start here before posting Help your fellow Redditors crack the electrical code. Talk shop, show off pictures of your work, and ask code related questions. Reddit's International Electrical Worker CommunityĪka The Great Reddit Council of Electricians In this photo, have a piece of paper with your username and date written on it. To get verified, send a photo to the mods that has your certificate/seal/card. Users with have verified their qualifications with the Mods Then message the mods with the country you are from. She turns the key to start the generator and the transfer panel takes care of the load management.To add your country's flag to your flair, you must select a title from the drop down menu. Good for when I'm not home and my wife is here alone. APC was ~$400 when I bought it way back when. Longest outage we've had was 8 days in the summer and 5 days in the winter. I've had it for over a dozen years with no issues. But pretty much every other 120v circuit in my house can be powered kitchen bathrooms, bedrooms, offices, home theater, etc. The 240v circuit runs my well pump, the way I wired it up the well pump is the only 240v in my house that can be powered by the my generator, a Honda eu6500. It load sheds as needed, as you have programmed it. You can wire quite a few circuits in, it's programmable so you enter your circuit priority for load shedding, etc. Slight tangent.I have na APC panel for my generator, the APC Universal Transfer Switch 10-Circuit – Bypass switch – AC 120/240 V. They can then stone right around the chunk of wood or the PVC. Use the PVC as a sleeve to run your conduit through when you mount the surface-mounted box. If you want to surface mount, run a piece of PVC pipe through the wall. The gap between the two pieces and the sill seal will give you wiggle room to remove the pieces later on. Wrap the of wood with a couple wrappings of foam sill seal. Maybe run the 2圆 through the table saw to cut it in two, then screw the two pieces to the sheathing with a slight gap between them. If you want to flush mount it, I'd also consider mounting a piece of 2x4 or 2圆 the appropriate size, screwed into the wall sheathing at the proper location. One problem here is that the PB30 mounting holes don't line up well w/ the gang box - maybe drill my own holes and screw directly into stone and cover the gang box w/ surface mount PB30.? (I could also rotate the gang box 90* horizontal and give me more space above below for mounting PB30 into stone and still cover up gang box on sides.)Īppreciate your input on options for mounting a Reliance PB30 on/in stone exterior siding - thanks Transfer Switch Kit for Gen Ready Load Center. Or I can put a single gang box (or 2 gang) and push a little extra wire inside if I need to pull some excess out and mount the PB30 box on top of the gang box. i have installed a couple of transfer swithches where there is no drywall for a buddy of mine his panel has drywall around it, for the people that have come. 30 Amp 125/250-Volt 7,500-Watt 1-Circuit Manual Transfer Switch. This would give me lots of stone to drill into for a secure surface mount. Or leave a simple 'hole' in the stone siding and let the wire come thru (stub a piece of gray conduit there) and surface mount directly to the stone. I'd probably have it stand proud of the stone by about 1-inch. If so they would have to leave a 3/4" or so gap above the plug so I can lift the cover off. QUESTION: Is flush mounting in stone siding reasonable? Or bad idea? They are starting on the stone siding and the stone masons can set it in the stone. I picked up a Reliance PB30 input plug receptacle. (then I can manually select just a few pre-identified circuits at the sub-panel to power up, staying within the capacity of the portable generator. I'll then be able to wheel a portable generator out the driveway, around the corner and plug it into the input plug if needed during an extended power outage. This will be wired to the sub-panel inside the garage where there will be an inter-lock switch. I am pre-wiring a 30A input plug on the side of the garage. In construction phase of new house and garage.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |